Enerdrive ePOWER B-TEC 100Ah Lithium Battery & 40A AC2AC Charger Pack 
 
Package Includes:
1x Enerdrive ePOWER B-TEC 100Ah G2 Lithium Battery with a Battery Strap
1x Enerdrive ePOWER 12V 40A  Battery Charger

 

ePOWER B-TEC LiFeP04 12v 100Ah Lithium Battery

Available in 12v 100Ah, 125Ah, 200Ah and 300Ah capacities and 24v & 36v 100Ah, the ePOWER B-TEC lithium battery is designed and intended for use in deep cycle applications where a single battery is required that meets the amp hour capacity.

Smart Phone Monitoring System

The Enerdrive ePOWER B-TEC battery incorporates wireless Battery Monitoring Technology. By downloading the Android™ or Apple® app to your smartphone or tablet device, you can monitor the following information;

  • Battery Capacity
  • Battery Voltage
  • Battery Current (Amps)
  • Battery State of Charge (SOC)
  • Battery State of Health (SOH)
  • Battery Status
  • Individual Cell Voltage
  • Battery Temperature
  • Battery Cycles
  • Battery Alarms
  • Battery Event Information

Battery Management System

The battery is also equipped with an internal Battery Management System that can monitor and optimise each Prismatic cell within the battery during normal operation. It will protect the battery pack from over charge, over discharge, over temperature & short circuit. The BMS helps to ensure safe and accurate operation of the battery.

Size & Weight Savings

Lithium v AGM Capacities;

  • 100Ah Lithium = 160Ah AGM
  • 125Ah Lithium = 200Ah AGM
  • 200Ah Lithium = 320Ah AGM
  • 300Ah Lithium = 480Ah AGM

(Based on standard depth of discharge for both Lithium (80%) and AGM (50%).

The ePOWER B-TEC battery provides 60% more usable power than its equivalent lead acid cousin and being nearly 50% lighter and 30% smaller makes for a superior alternative.

The ePOWER B-TEC battery is perfect for camper trailers, 4WD’s (AUX battery), caravans, small water craft, low power communication sites or any other application that requires the use of a single deep cycle battery that meets the amp hour capacity.

With over 7 years of researching, designing and testing lithium batteries and the associated charging systems, Enerdrive are at the forefront of lithium battery systems in Australia. Enerdrive are the only Australian company that can supply a fully integrated self-branded energy system to suit your setup.

With over 3000 complete systems in operation Australia wide, Enerdrive is regarded as the leader in the field of lithium batteries and energy systems for Mobile, Marine and Remote applications.

Please Note; The B-TEC battery is capable to be paralleled to a second B-TEC battery of the same size. For maximum performance and lifespan of your B-TEC battery, no more than 2 batteries should be connected together to increase your overall capacity. Overall loads when paralleled should not exceed the current limits of a single batteries BMS.

The 100Ah battery is able to accept a maximum inverter capacity of 1000W only. Exceeding the maximum inverter capacity can damage the BMS Management within the battery.

If you are requiring a battery system larger than ePOWER B-TEC battery, please look at the Enerdrive Pro Series Power Pack Systems which can offer multiple parallel and series connections with Active Cell Balancing Protection across the entire pack.

 

 

Specifications

Enerdrive B-TEC 12v Lithium Battery Technical Data

Normal Specification EPL-100BT-12V EPL-125BT-12V EPL-200BT-12V EPL-300BT-12V
Nominal Voltage 12.8V
Nominal Capacity 100Ah 125Ah 200Ah 300Ah
Cycle Life (DOD – 80% under controlled conditions) ≥ 2000 Cycles
Standard Charge Specification (Lithium profile charger required)
Battery Charge Temperature 0 ̴ 45°C
Normal Charge Voltage CV/CC* 14.40 ̴ 14.60V
Standby (Float) Voltage 13.50 ̴ 13.80V
Maximum Charge Current 50A @ 25°C for 30mins 60A @ 25°C for 30mins 150A @ 25°C for 30mins 150A @ 25°C for 30mins
Recommended Charge Current for Maximum Life ≤33A ≤40A ≤60A ≤90A
Standard Discharge Specification
Battery Discharge Temperature -20 ̴ 60°C
Battery Output Voltage Range 11.00 ̴ 14.60V
Maximum Discharge Current 100A @ 25°C ± 5°C for 30mins 100A @ 25°C ± 5°C for 30mins 200A @ 25°C ±5°C for 30mins 200A @ 25°C ±5°C for 30mins
Pulse Discharge Current 450A for 1.0s
Discharge Cut-off Voltage ≤11.20V
Circuit Protection The battery is supplied with a LiFePO4 Battery Management System BMS that can monitor and optimize each single prismatic cell during charge & discharge, to protect the battery pack from overcharge, over discharge & short circuit. Overall, the BMS helps to ensure safe and accurate operation of the battery.
Over-Charge Protection
Over-charge Protection Per Cell 3.90V ± 0.03V
Over-charge Release Per Cell 3.60V ± 0.05V
Over-charge Release Method Discharge below release voltage
Over-Discharge Protection
Over-discharge Protection Per Cell 2.80V ± 0.05V
Over-discharge Release Per Cell 3.20V ± 0.05V
Over-discharge Release Method Apply Charge/Voltage ≥12.8V
Battery Manual Reset Button No No No No
Over Current Protection
Discharge Over Current 110A for 30s – 450A for 1s 110A for 30s – 450A for 1s 220A for 30s – 450A for 1s 220A for 30s – 450A for 1s
Protection Reset Time 5s Auto Release
Over Current Release Method Disconnect Load
Over Temperature Protection
Battery Discharge Over Temperature Protection to 65°C ± 5°C
  Release at 50°C ± 5°C
Battery Charge Over Temperature Protection to 55°C ± 5°C
  Release at 45°C ± 5°C
Short Circuit Protection Auto release after 5s
Mechanical Characteristics
Dimensions Length 318mm 485mm 519mm
  Width 165mm 170mm 273mm
  Height 215mm 245mm 222mm
Weight Approx 12.6 Kg Approx 15.0 Kg Approx 25.0 Kg Approx 37.7 Kg
Storage Information
Temperature & Humidity Range ≤ 30 days -20°C ̴ 60°C, 5 ̴ 75% RH
  ≥ 90 days -10°C ̴ 45°C, 5 ̴ 75% RH
Self-discharge Rate ≤ 3% Per Month

Note: Specifications subject to change without notice.

 

 

ePOWER 12V 40A Battery Charger

40A Battery Charger Features:

  • Multistage Charging: Fully automatic multistage battery charger with the ability to charge 3 separate battery banks.
  • Separate Battery Banks: Isolated charging design where battery bank one is separate from battery bank two and three.
  • Programmable: Battery bank 1 can be programmed with a different charge algorithm over banks 2 and 3.
  • Current Control: User adjustable current output (e.g. Dial the 60amp unit back to run off a 1kVA generator).
  • Smart Charging: The ePOWER 40A battery charger will regulate its output based on the loads connected to your battery banks.
  • Wide AC Input Range: Operates on both 110V / 60Hz and 240V / 50Hz.
  • LED Display: Easy to use “set and select” menu along with scrolling charger status.
  • Silent Mode: Disables the cooling fan for total silent operation at night or whenever required. Activation reduces charge output by half and locks out fan for 12 hours.
  • Temperature Sensor: Battery temperature sensor included with 3 meter cable.
  • 5 Year Manufacturer Warranty from an Australian company renowned for customer support.

Multistage Charging Process

The Enerdrive ePOWER 40A Battery Charger is a fully automatic, “set and forget” charger. It is designed to quickly and accurately recharge your batteries using algorithms that help maximise service life. Multistage smart charging technology enables the charger to be connected to your battery banks permanently.

As dictated by battery manufacturer’s recommendations, batteries require a multistage charge sequence for perfect, fast and accurate charging. Our ePOWER multistage smart 40A battery charger delivers four primary charge stages:-

  • Stage 1 – Bulk or Boost Charge; The battery is charged at full rated output current of the charger until the battery reaches its final charging voltage, known as its absorption voltage. In this step, around 80% of the battery capacity is recovered as fast as possible.
  • Stage 2 – Absorption Charge; With the charger voltage held steady the remaining 20% is replaced allowing the current to drop as the battery approaches its full charge.
  • Stage 3 – Float; Finally, in the float stage the charger voltage is lowered and held at a constant and safe predetermined level. This prevents the battery from being overcharged while supporting any additional loads connected to the battery, such as DC lighting and refrigerators. This stage allows for the charger to be used as a DC power supply.
  • Stage 4 – Maintenance; This stage is a regular timed “return to bulk” stage. After 7 days of constant operation in “float” the Enerdrive ePOWER Battery Charger will switch the charger from float to bulk to agitate the batteries electrolyte helping to provide an extended service life.

 1 PRIORITY – Charge Where You Need it Most

The ePOWER 40A Battery Charger delivers a priority charge to Bank 1, or your main house battery bank which allows the charger to get this bank recharged the quickest, then transition the cycle to the lesser bank 2 & 3 batteries.

The priority function also allows you to have a battery chemistry different to the other two, such as an AGM battery for house and lead calcium for your start banks.

In the event that all 3 banks are in need of a charge, an over-ride function helps recover all 3 banks quickly and evenly before switching back to prioritise on Bank 1.

All About Lithium

The recent advances in high capacity Lithium battery technology have seen the need to develop a battery charger suited to their needs. With most traditional ‘smart’ chargers their suitability to Lithium batteries is limited. Lithium batteries require a constant current / constant voltage charge algorithm and are unique in that almost every amp-hour of charge delivered by the charger is accepted as one amp hour into the battery, hence the need to deliver a constant current as long as possible.

The Enerdrive ePOWER charger can be programmed for Lithium batteries. This setting delivers the full rated output of the charger constantly with the charger switching to power supply mode once the voltage peak is met (indicating a full battery bank). The graph shows the ePOWER charger algorithm perfectly supporting Lithium battery requirements.

The Display Panel

The ePOWER 40A Battery Charger display gives you all the information you need for the operation of your charger. At a glance, key information such as charger amps, battery voltage and charge state continually alternate on the screen.When in float / power supply mode, the load amps are displayed so you can see exactly what the charger is doing. The display also allows you to program all settings of the charger, as well as activate the silent mode.

Silence when you need it – By pressing the “SEL” button for 5 seconds, the ePOWER Charger enters the ‘Silent’ mode that prohibits the fan from working. This ensures totally silent and safe operation at night, ideal if the charger is located close to your sleeping quarters. Silent mode limits current output to no more than 50%, and is programmed to remain on for 12 hours before automatically returning to a normal ‘fan-on & full output’ setting.

 

 

Specifications

Enerdrive ePOWER Battery Charger Specifications

Model EN31220 EN31240 EN31260 EN32430
CHARGER OUTPUT
Output Current (Maximum) 20A 40A 60A 30A
OUTPUT VOLTAGE RANGE
Charge 14.2 – 15.5 V 28.4 – 31.0V
Float 13.4 – 13.8 V 26.8 – 27.6V
– Equalize 16.0 V 32.0V
Charging Control Four stages (Bulk/Absorption/Float/Maintenance)
  Two stages (Bulk/Absorption)
  Constant Power Supply (Program setting)
  Priority Battery Bank Charging
DC Output Bank Three (1 fully independent, 2 common with diode isolation)
Selectable Battery Type Gel, AGM, Flooded, Lithium, Program
Standby Current < 2 mA
CHARGER INPUT
AC Input Voltage (Nominal) 90 to 265 VAC
AC Input Operating Range 207-265 Vac (2.0 A Max)90-125 Vac (3.8 A Max) 207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max) 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) 207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max)
AC Input Frequency Range 47 – 63 Hz
Power Consumption 350W (Full Load) 700W (Full Load) 1050W (Full Load) 1050W (Full Load)
Power Factor Correction Yes
Charger Efficiency > 82%
PROTECTION AND FEATURES
Reverse Polarity Yes, (with user replaceable fuse/s)
Over Charge Yes, unit shutdown
Over Temperature Yes, unit de-rated and shutdown
Output Short Circuit Yes, (with user replaceable fuse/s)
Cooling Forced air ventilation (thermo controlled fan)
Temperature Setting Hot, Normal, Cold (no sensor connected)
Battery Temp Sensor Port RJ12 (standard battery temp. sensor supplied)
DISPLAY
LCD Display (with back light) Charging status, Battery Voltage, Output Current & Fault Codes.
AC INPUT AND DC OUTPUT CONNECTION
AC Input Connection IEC with Supplied 1.2M Power Lead
DC Output Connection Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread
DC Output Ground Single Heavy Duty Common Ground Stud
ENVIRONMENTAL AND OPERATING TEMPERATURE
Storage Range -40° to 70° C
Operating Range -20° to 60° C
Humidity 5-95%, relative humidity non-condensing
Ingress Protection IP32 (Basic drip proof in vertical orientation)
  Base Unit Weight and Dimensions
Weight: (kg) 2.4 2.6 4 4
Dimension: (mm) L x W x H 295 x 206 x 86 295 x 206 x 86 356 x 206 x 99 356 x 206 x 99
Optional Accessories Remote Digital Display / Enerdrive Part Number EN3REM
Regulatory Compliance Complies with AS/NZS 60335.2.29 Including Australian deviations.

Note: Specifications subject to change without notice.

SKU K-100-AC-BUNDLE
Model # K-100-AC-BUNDLE
Brand Enerdrive
Type Charger

Be The First To Review This Product!